Large-volume bell lift type furnaces

Large-volume bell lift type furnaces

Large-volume bell lift type furnaces

This type of furnace is designed for serial or large-scale production, as well as for processing large products. A design feature of this type of furnace is a monoblock assembled heating unit, mounted on the walls and cover of the hood, so that the heating unit rises with the hood. Two powerful screw hoists provide a smooth rise and lowering of each hood. Thanks to the precision execution of the mechanical assembly of the lifting mechanism, any jerking, seizing and vibration are practically eliminated.

After raising the hood, horizontal loading of the cages with products under the hood is possible, which is especially true with a large mass of parts. With this configuration, a phased installation of the cage and parts in the cage is possible, which significantly increases the number of products.

As a rule, such furnaces are made by double-bell with alternating heating caps. Heating elements can be of a cylindrical and wire type, from high-temperature alloys of resistance (nichrome, eurofechral, kanthal A1), molybdenum, less often from tungsten. It is possible to install an all-welded heater of complex design made of tungsten or molybdenum. The large volume of the chamber allows the manufacture of furnaces of this design with multi-zone heating.

Parameter name

Value

Chamber quantity, items

2

Type of chambers:

cylindrical, vertically oriented

Inner dimensions of chamber:

- d, mm:

- h, mm:

250...400

300...700

Temperature in the working chamber оС:

-control thermocouples ХА (K) or НН (N):
-control thermocouples PP (S) or PR (B):
-control thermocouples BP (A1) or BP (C):

50...1250

50...1600

600...2000

Heating type

resistive

Permissible mass with parts, kg:

10...80

Available oxygen removal methods:

purging with nitrogen or inert gas, evacuation pumping, multi-stage

Range of heating / cooling speeds, ° C / min:

3…25

Working gases:

hydrogen, helium, nitrogen, argon, methane, formgas

Number of inputs for working gases:

2...6

Available operations with working gases:

mixing, moisturizing

Minimum percentage of each gas when mixed:

5%

Range of automatic adjustment of the flow rate of each gas, l / min:

50...1200

Ability to use as a vacuum or gas vacuum furnace:

yes

Types of pumping systems:

oil (rotary vane + diffusion pumps), oil-free (dry scroll + turbomolecular pumps)

The uniformity of temperature in the working space without loading the electric furnace with automatic control of maintaining the temperature in the steady state, ° C, is not worse:

±7±0,005t

Stability of maintaining the operating temperature in the working area when controlling heating in automatic mode, ° C, not worse:

±5±0,0015t

Heaters power consumption,kVA

35...100

Total dimensions, mm, no more than:

- length:

- width

- high

2600

1600

2850

Weight, kg, no more than

3750

Documents